  Street light controller is composed of photoelectric conversion device, relay and etc., which can effectively reduce the consumption of manpower and electricity, so street light is widely used in street lights (factories, schools, streets, airports, farms), and navigation lights on islands. Our street lamp controller has the advantages of strong anti-interference ability, reliable function and high sensitivity, and its work is not affected by the weather and season. Our street light controller is equipped with a delay circuit inside, so it can prevent switching errors action caused by accidental bright lights (such as lightning, flashlights, car lights and other illuminating light sources) and accidental obstructions (such as fallen leaves). AS series street light controller adopts a plastic shell, and it is small in size, good in water resistance, light in weight, but weak in switching capacity. GUK series street light controller adopts a metal shell, and it has strong anti-interference ability and strong switching capacity. KG-F series can be installed on the DIN Rail.

Parameters


AS-10 (Optical Control)

Operation Voltage: AC220V/50Hz (or other customized voltage)
Operation Temperature: -10℃~60℃
On-off illumination: 10LX±1LX
Switching Capacity: 5A (resistive load)
Dimensions: 120×80×80mm

AS Series AS-10 (Optical Control) image

AS-15 (Optical Control)

Operation Voltage: AC220V/50Hz (or other customized voltage)
Operation Temperature: -10℃~60℃
On-off illumination: 10LX±1LX
Switching Capacity: 15A (resistive load)
Dimensions: 120×80×80mm

AS SeriesAS-15 (Optical Control) image

AS-20 (Optical Control)

Operation Voltage: AC220V/50Hz (or other customized voltage)
Operation Temperature: -10℃~60℃
On-off illumination: 10LX±1LX
Switching Capacity: 7A (resistive load)
Dimensions: 65×65×70mm

AS Series AS-20 (Optical Control) image

ASO (Optical Control)

Operation Voltage: AC220V/50Hz (or other customized voltage)
Operation Temperature: -10℃~60℃
On-off illumination: 10LX±1LX
Switching Capacity: 10A (resistive load)
Dimensions: 50x50×70mm

AS Series ASO (Optical Control) image

GUK-81 (Optical Control)

On-off delay: 10s-60s
On-off illumination: 10LX (adjustable)
Operation Voltage: AC220V/50Hz (or other customized voltage)
Rated Current: 10A
Operation Temperature: -10℃~60℃
Weight: 1.1kg
Working Mode: Automatic
Dimensions: 96×104×246mm
Mounting: Wall

GUK Series GUK-81 (Optical Control) image

GUK-82 (Optical Control)

On-off delay: 10s-60s
On-off illumination: 10LX (adjustable)
Operation Voltage: AC220V/50Hz (or other customized voltage)
Rated Current: 40A
Operation Temperature: -10℃~60℃
Weight: 1.5kg
Working Mode: Automatic
Dimensions: 90×104×246mm
Mounting: Wall

GUK Series GUK-82 (Optical Control) image

GUK-83/84 (Optical Control)

On-off delay: 10s-60s
On-off illumination: 10LX (adjustable)
Operation Voltage: AC220V/50Hz (or other customized voltage)
Rated Current: 60A/80A
Operation Temperature: -10℃~60℃
Weight: 2.1kg
Working Mode: Automatic
Dimensions: 83: 113×112×275mm; 84: 335×135×155mm
Mounting: Wall

GUK Series GUK-83/84 (Optical Control) image

KG-F (Optical Control)

On-off delay: 10s-60s
On-off illumination: 10LXL (adjustable)
Operation Voltage: AC220V/50Hz (or other customized voltage)
Operation Temperature: -10℃~60℃
Switching Capacity: 20A (resistive load)
Dimensions: 120×74×51mm
Mounting: Wall

KG-F Series KG-F (Optical Control) image

Dimensions & Wiring Diagram


AS Series

1 Installation method
The correct installation method is shown in Figure 1; the wrong installation method is shown in Figure 2.
2 Wiring method
PORT 1 (White) and PORT 2 (Black) are connected to the power supply; PORT 1 (White) and PORT 3 (Red) are connected to the load. For inductive loads (such as fluorescent lamps, high pressure sodium lamps, mercury lamps, metal halide lamps), a current stabilizer should be connected in parallel at the output (Figure 3). For resistive loads (such as incandescent lamps, iodine tungsten lamps, etc.), there is no need to add a current stabilizer (Figure 4).

AS Series Mounting and wiring diagram

Mounting and wiring diagram 1

GUK Series

1 Installation method
Install the GUK series street lamp controller on a street lamp post or a place with natural light. The sensitivity knob is used to adjust the sensitivity of the photosensitive circuit (Figure 5).
2 Wiring method
PORT 1 and PORT 3 are connected to the power supply; PORT 2 and PORT 3 are connected to the load (Figure 6). If the load is an inductive load, a current stabilizer must be connected in parallel at the output terminal.

KG-F Series

1 Installation method
Install the KG-F series street light controller on an indoor wall or DIN Rail, and then place its light control probe outdoors to sense changes of the natural light.
2 Wiring diagram
Direct control wiring method (Figure 7); expansion wiring method (Figure 8).

GUK Series KG-F Series Mounting and wiring diagram

Mounting and wiring diagram 2

Attentions


1 Please clean the dust on the light control probe in time or regularly to avoid affecting the photoelectric conversion effect.
2 Please do not repair, disassemble or modify this product by yourself. If you need repair and inspection, please entrust a dealership or other authorized unit.
3 Do not touch any terminals after turning on the power.