MGR-1 Series
Panel Mount Solid State Relay
[All the information on this website is for reference only, and the actual product and the accompanying product manual shall prevail. If you have any questions, please contact webmaster@huimultd.com.]
Introduction
The MGR-1 series 1 Channel / Single Channel Panel Mount Solid State Relay uses the Standard Package (rectangular shape, TRIAC as the output component). According to the load power supply, it is divided into MGR-1 series One Channel DC Panel Mount SSR, MGR-1 series Single Phase AC Panel Mount SSR. According to the I-O (Input-Output) signal, the MGR-1 series can be divided into MGR-1DD Series (DC-DC), MGR-1AD Series (AC-DC), MGR-1D Series (DC-AC), MGR-1A Series (AC-AC). According to the trigger mode, the MGR-1 series solid state relay can be divided into MGR-1 series zero-crossing SSR (or zero cross switching SSR), and MGR-1 series random turn-on SSR (or random fire SSR,). The model number of the MGR-1 zero-crossing turn on solid-state relay is end with "Blank" or "Z"; the model number of the MGR-1 random turn on solid-state relay is end with "P".
- Updates:
-(2021/03/05) We have redesigned the MGR-1DD110D series, and its load voltage range can cover most equipment requirements. Therefore, we will no longer produce MGR-1DD48D series and MGR-1DD60D series.
How to order
MGR-1(Panel Mount, Single Channel, Standard Package)
- [Input-Output] {DD (DC-DC, One Channel); AD (AD-DC, One Channel); D (DC-AC, Single Phase); A (AC-AC, Single Phase)}
- [Load Voltage]
- [Rated Current]
- [Function] {Z (Zero Crossing); P (Random Fire)}Parameters
MGR-1DD Series (DC to DC, Small Current)
Control Voltage: 3~32VDC (such as 3VDC, 5VDC, 9VDC, 12VDC, 18VDC, 24VDC, 32VDC or customized control voltage)
Control Current: Low input current, ≤40mA
Load Voltage: One channel, 5~220VDC (such as 5VDC, 6VDC, 8VDC, 9VDC, 12VDC, 18VDC, 24VDC, 36VDC, 42VDC, 48VDC, 72VDC, 96VDC, 120VDC,180VDC, 220VDC or customized voltage)
Load Current: 10A, 20A, 25A, 30A, 40A, 50A, 60A, 75A, 80A, 90A, 100A, 120A
Dimensions & Mounting: 57.4mm*44.8mm*28mm; Panel mount solid state relay with transparent cover, metal base and screw terminalsMGR-1DD Series (DC to DC, Large Current)
Control Voltage: 3~32VDC (such as 3VDC, 5VDC, 9VDC, 12VDC, 18VDC, 24VDC, 32VDC or customized control voltage)
Control Current: Low input current, ≤40mA
Load Voltage: One channel, 5~110VDC (such as 5VDC,9VDC,12VDC,18VDC,24VDC,36VDC,48VDC,55VDC,60VDC, 72VDC, 96VDC, 110VDC or customized voltage)
Load Current: 150A, 200A, 300A, 400A, 500A, 600A, 800A
Dimensions & Mounting: 105mm*74mm*33mm; Panel mount solid state relay with transparent cover, metal base and screw terminalsMGR-1AD Series (AC to DC)
Control Voltage: 70~280VAC (such as 85VAC, 100VAC, 110VAC/120VAC, 200VAC, 220VAC/230VAC, 240VAC or customized control voltage)
Control Current: Ultra low input current, ≤10mA
Load Voltage: One channel, 5~220VDC (such as 5VDC, 12VDC, 24VDC, 36VDC, 72VDC, 84VDC, 96VDC, 120VDC or customized voltage)
Load Current: 10A, 20A, 25A, 30A, 40A, 50A, 60A, 75A, 80A, 90A, 100A, 120A, 150A
Dimensions & Mounting: 57.4mm*44.8mm*28mm; Panel mount solid state relay with transparent cover, metal base and screw terminalsMGR-1D Series (DC to AC)
Control Voltage: 3~32VDC (such as 3VDC, 9VDC, 12VDC, 24VDC, 32VDC or customized control voltage)
Control Current: Ultra low input current, ≤10mA
Load Voltage: Single phase 24~1200VAC (such as 24VAC, 48VAC, 110VAC, 230VAC, 380VAC, 480VAC or customized voltage)
Load Current: 10A, 20A, 25A, 30A, 40A, 50A, 60A, 75A, 80A, 90A, 100A, 120A, 150A
Dimensions & Mounting: 57.4mm*44.8mm*28mm; Panel mount solid state relay with transparent cover, metal base and screw terminalsMGR-1A Series (AC to AC)
Control Voltage: 85~265VAC (such as 100VAC, 110VAC/120VAC, 200VAC, 220VAC/230VAC, 240VAC or customized control voltage)
Control Current: Ultra low input current, ≤10mA
Load Voltage: Single phase 24~1200VAC (such as 24VAC, 48VAC, 110VAC, 230VAC, 380VAC, 480VAC or customized voltage)
Load Current: 10A, 20A, 25A, 30A, 40A, 50A, 60A, 75A, 80A, 90A, 100A, 120A, 150A
Dimensions & Mounting: 57.4mm*44.8mm*28mm; Panel mount solid state relay with transparent cover, metal base and screw terminalsFeatures
MGR-1DD Series
● Easy to connect in parallel, suitable for high current applications
● Low output off-state leakage current
● Low-impedance MOSFET as the output component minimize the total power consumption
● Suitable for resistive load and inductive load (the inductive load, such as motor and EMR /electromagnetic coil, must be equipped with the suppressor diode)
● Display output status via LED
● Standard output RC snubber circuit
● Transparent cover for extra protectionMGR-1AD Series
● Low output off-state leakage current
● Low-impedance MOSFET as the output component minimize the total power consumption
● Suitable for resistive load and inductive load (the inductive load, such as motor and EMR /electromagnetic coil, must be equipped with the suppressor diode)
● Display output status via LED
● Standard output RC snubber circuit
● Transparent cover for extra protectionMGR-1D Series
● TRAIC as the output component can be used in commercial or heavy industrial applications with reliable performance
● "Ultra-low" input current
● Low output off-state leakage current
● Low output on-state voltage drop
● Availed with zero-crossing conduction (resistive load) or random conduction (inductive load or phase control)
● Display output status via LED
● Standard output RC snubber circuit
● Transparent cover for extra protectionMGR-1A Series
● TRAIC as the output component can be used in commercial or heavy industrial applications with reliable performance
● "Ultra-low" input current
● Low output off-state leakage current
● Low output on-state voltage drop
● Availed with zero-crossing conduction (resistive load) or random conduction (inductive load or phase control)
● Display output status via LED
● Standard output RC snubber circuit
● Transparent cover for extra protectionDimensions and Circuit Wiring Diagram
MGR-1DD Series Panel Mount Solid State Relay
DC-DC, Small Current
DC-DC, Large Current
MGR-1AD Series Panel Mount Solid State Relay
AC-DC
MGR-1D Series Panel Mount Solid State Relay
DC-AC, Zero-Crossing
DC-AC, Random-Fire
MGR-1A Series Panel Mount Solid State Relay
AC-AC
Application
● Various commercial and industrial equipment that requires an electronic switch, especially but not limited to air conditioners, balers, household appliances, heating or cooling equipment, professional food equipment, medical machines, remote control system, automotive, lighting system, motion control system, numerical control machinery.
Precautions and FAQs
● If the load current is 10A, a heat sink must be equipped; if the load current is 40A or more, an air-cooled radiator or a water-cooled radiator must be installed.
● When the load is an inductive load, be sure to connect a varistor in parallel with the output terminal, whose voltage value is 1.6-1.9 times the load voltage.
● What are the differences between Panel mount SSR and PCB mount SSR?
The panel type solid state relay (or device type, screw mounting type) needs to be fixed on a metal base plate or a heat sink, and is cooled by a heat sink or an air-cooled radiator. The PCB solid state relay (or pin mounting type) has the industry standard pin configurations, and can be mounted directly to the Printed Circuit Board, and the natural cooling as heat dissipation without the need for a heat sink. The PCB type has a smaller mounting size and a larger power density than the panel type.
● What is the difference between a Standard Package SSR (TRIAC output) and an Industrial Package SSR (anti-parallel SCR output)?
For resistive AC loads, the difference between the two is small. Standard Package can use up to M5 screws, while Industrial Package can use up to M8 screws.
For inductive or capacitive AC loads, when the solid state relay is turned off in the on state, a large voltage-rise rate dv/dt (commutation dv/dt) will occur due to the inconsistent phase of the current and voltage. Such dv/dt affects the output efficiency of TRIAC, or even damages TRIAC, but the effect of commutation dv/dt on anti-parallel SCR is very small. Therefore, for AC loads with large inductance or capacitance, it is more suitable to choose industrial solid state relays.
● What is the difference between Zero Cross Switching and Random Fire Switching?
According to the trigger timing, the trigger mode of the solid state relay can be divided into Zero Cross Switching (or Zero-crossing Turn-on) and Random Fire Switching (or Random Turn-on). When the Zero Crossing Turn-on SSR receives the control signal, it will switch the load after the load voltage passes the zero-crossing point (which is not a voltage point but actually a voltage zone, about ±15V), which helps to reduce EMI, RFI and the impulse current; Random Turn on SSR will switches the load immediately (in few milliseconds) as soon as it receives the control signal, so it is more suitable for applications with higher delay requirements.All Regular Models We Offer
● MGR-1DD Series (One Channel, DC to DC)
Load Voltage 5-110VDC
- MGR-1DD110D10
- MGR-1DD110D20
- MGR-1DD110D25
- MGR-1DD110D30
- MGR-1DD110D40
- MGR-1DD110D50
- MGR-1DD110D60
- MGR-1DD110D75
- MGR-1DD110D80
- MGR-1DD110D90
- MGR-1DD110D100
- MGR-1DD110D120
- MGR-1DD110D150
- MGR-1DD110D180
Load Voltage 5-220VDC, Small Current
- MGR-1DD220D10
- MGR-1DD220D20
- MGR-1DD220D25
- MGR-1DD220D30
- MGR-1DD220D40
- MGR-1DD220D50
- MGR-1DD220D60
- MGR-1DD220D75
- MGR-1DD220D80
- MGR-1DD220D90
- MGR-1DD220D100
- MGR-1DD220D120
Load Voltage 5-110VDC, Large Current
- MGR-1DD110D150
- MGR-1DD110D200
- MGR-1DD110D300
- MGR-1DD110D400
- MGR-1DD110D500
- MGR-1DD110D600
- MGR-1DD110D800
Load Voltage 5-60VDC, Large Current
- MGR-1DD60D200
- MGR-1DD60D300
- MGR-1DD60D400
- MGR-1DD60D600
● MGR-1AD Series (One Channel, AC to DC)
Load Voltage 5-120VDC
- MGR-1AD12D10
- MGR-1AD12D20
- MGR-1AD12D25
- MGR-1AD12D30
- MGR-1AD12D40
- MGR-1AD12D50
- MGR-1AD12D60
- MGR-1AD12D75
- MGR-1AD12D80
- MGR-1AD12D90
- MGR-1AD12D100
- MGR-1AD12D150
Load Voltage 5-220VDC
- MGR-1AD22D10
- MGR-1AD22D20
- MGR-1AD22D25
- MGR-1AD22D30
- MGR-1AD22D40
- MGR-1AD22D50
- MGR-1AD22D60
- MGR-1AD22D75
- MGR-1AD22D80
- MGR-1AD22D90
- MGR-1AD22D100
● MGR-1D Series (Single Phase, DC to AC)
Load Voltage 24-480VAC, Zero Crossing
- MGR-1D4810
- MGR-1D4820
- MGR-1D4825
- MGR-1D4830
- MGR-1D4840
- MGR-1D4850
- MGR-1D4860
- MGR-1D4875
- MGR-1D4880
- MGR-1D4890
- MGR-1D48100
- MGR-1D48120
- MGR-1D48150
Load Voltage 24-690VAC, Zero Crossing
- MGR-1D6910
- MGR-1D6920
- MGR-1D6925
- MGR-1D6930
- MGR-1D6940
- MGR-1D6950
- MGR-1D6960
- MGR-1D6975
- MGR-1D6980
- MGR-1D6990
- MGR-1D69100
- MGR-1D6969
- MGR-1D69150
Load Voltage 24-1200VAC, Zero Crossing
- MGR-1D12010
- MGR-1D12020
- MGR-1D12025
- MGR-1D12030
- MGR-1D12040
- MGR-1D12050
- MGR-1D12060
- MGR-1D12075
- MGR-1D12080
- MGR-1D12090
- MGR-1D120100
- MGR-1D120120
- MGR-1D120150
Load Voltage 24-480VAC, Random Fire
- MGR-1D4810P
- MGR-1D4820P
- MGR-1D4825P
- MGR-1D4830P
- MGR-1D4840P
- MGR-1D4850P
- MGR-1D4860P
- MGR-1D4875P
- MGR-1D4880P
- MGR-1D4890P
- MGR-1D48100P
- MGR-1D48120P
- MGR-1D48150P
Load Voltage 24-690VAC, Random Fire
- MGR-1D6910P
- MGR-1D6920P
- MGR-1D6925P
- MGR-1D6930P
- MGR-1D6940P
- MGR-1D6950P
- MGR-1D6960P
- MGR-1D6975P
- MGR-1D6980P
- MGR-1D6990P
- MGR-1D69100P
- MGR-1D6969P
- MGR-1D69150P
Load Voltage 24-1200VAC, Random Fire
- MGR-1D12010P
- MGR-1D12020P
- MGR-1D12025P
- MGR-1D12030P
- MGR-1D12040P
- MGR-1D12050P
- MGR-1D12060P
- MGR-1D12075P
- MGR-1D12080P
- MGR-1D12090P
- MGR-1D120100P
- MGR-1D120120P
- MGR-1D120150P
● MGR-1A Series (Single Phase, AC to AC)
Load Voltage 24-480VAC, Zero Crossing
- MGR-1A4810
- MGR-1A4820
- MGR-1A4825
- MGR-1A4830
- MGR-1A4840
- MGR-1A4850
- MGR-1A4860
- MGR-1A4875
- MGR-1A4880
- MGR-1A4890
- MGR-1A48100
- MGR-1A48120
- MGR-1A48150
Load Voltage 24-690VAC, Zero Crossing
- MGR-1A6910
- MGR-1A6920
- MGR-1A6925
- MGR-1A6930
- MGR-1A6940
- MGR-1A6950
- MGR-1A6960
- MGR-1A6975
- MGR-1A6980
- MGR-1A6990
- MGR-1A69100
- MGR-1A6969
- MGR-1A69150
Load Voltage 24-1200VAC, Zero Crossing
- MGR-1A12010
- MGR-1A12020
- MGR-1A12025
- MGR-1A12030
- MGR-1A12040
- MGR-1A12050
- MGR-1A12060
- MGR-1A12075
- MGR-1A12080
- MGR-1A12090
- MGR-1A120100
- MGR-1A120120
- MGR-1A120150
*Customized models are available, be free to contact us.
Obsolete Models
● MGR-1DD Series (One Channel, DC to DC)
Load Voltage 5-48VDC
- MGR-1DD48D10
- MGR-1DD48D20
- MGR-1DD48D25
- MGR-1DD48D30
- MGR-1DD48D40
- MGR-1DD48D50
- MGR-1DD48D60
- MGR-1DD48D75
- MGR-1DD48D80
- MGR-1DD48D90
- MGR-1DD48D100
- MGR-1DD48D120
- MGR-1DD48D150
- MGR-1DD48D180
Load Voltage 5-60VDC
- MGR-1DD60D10
- MGR-1DD60D20
- MGR-1DD60D25
- MGR-1DD60D30
- MGR-1DD60D40
- MGR-1DD60D50
- MGR-1DD60D60
- MGR-1DD60D75
- MGR-1DD60D80
- MGR-1DD60D90
- MGR-1DD60D100
- MGR-1DD60D120
- MGR-1DD60D150
- MGR-1DD60D180
Tips
1) When selecting the rated current of the solid state relay/solid state module, please consider the corresponding Derating Factor.
2) You can visit Blog - Resourceto view and download files.
3) You can visit Productsto view and learn about other products.
4) You can visit Informationto view and learn about solid state relays/solid state modules knowledge.
5) You can also visit Help, or Contact usto get more support.