  KG316T series timer switch can automatically turn on or off the power of various electrical equipment according to the time set by the user. KG316T series digital time-controlled switch is consisted of digital LCD display, programmable IC chip, buttons, switching components and etc. KG316T series microcomputer timer switch is widely used in street lights, neon lights, advertising signs, production equipment, assembly lines, and broadcast equipment. The new version KG316T adopts a brand-new chip technology, which can effectively avoid the false welding and missing welding. Besides, the all-new designed KG316T has the characteristics of stable performance, low power consumption, light weight, and replaceable power supply battery. The function of KG316T-D series timer switch is similar to that of KG316T, but it adopts the wiring method of lower wiring. KG316T-Ⅱ series timer switch (mini size type) is an improved version of KG316T, and KG316T-Ⅱ has a smaller size and is suitable for applications that have higher requirements for installation space. KG316T-Ⅱ has a built-in nickel-hydrogen rechargeable battery to prevent the battery from running out if the battery cannot be replaced in time.

Parameters


KG316T (Single Output, Upper Wire)

Timer Range: 1min≤t≤168h (cycle work daily or weekly)
Operation Voltage: AC220V/50Hz (or other customized voltage)
Operation Temperature: -10℃~ 60℃
Operation Humidity: <95%
Switching Capacity: 25A (resistive load); 20A (inductive load)
Number of Settings: 10/16 groups per day, with anti-mistouch button lock
Control Mode: Manual, Auto
Consumption Power: ≤1W
Battery: 7AA battery
Time Error: ≤1s/day (25℃)
Weight: 260g
Dimensions: 120×74×58mm
Mounting: Wall/Rail

KG316T Series KG316T (Single Output, Upper Wire) image

KG316T-D (Single Output, Down Wire)

Timer Range: 1min≤t≤168h (cycle work daily or weekly)
Operation Voltage: AC220V/50Hz (or other customized voltage)
Operation Temperature: -10℃~ 60℃
Operation Humidity: <95%
Rated Current: 3A(220V), 1.9A(380V)
Load Power: 6KW (resistive load), 1.8KW (inductive load), 1.2KW (electric motor), 0.9KW (light)
Switching Capacity: 25A (resistive load); 20A (inductive load)
Number of Settings: 16 groups per day, with anti-mistouch button lock
Consumption Power: ≤2W
Battery: 5AA battery
Time Error: ≤2s/day (25℃)
Weight: 260g
Dimensions: 120×77×53mm
Mounting: Wall/Rail

KG316T Series KG316T-D (Single Output, Down Wire) image

KG316T-Ⅱ (Single Output, Mini Size)

Timer Range: 1min≤t≤168h (cycle work daily or weekly)
Operation Voltage: AC220V/50Hz (or other customized voltage)
Operation Temperature: -10℃~ 60℃
Operation Humidity: <95%
Rated Power: 2.5KW
Switching Capacity: 25A (resistive load); 20A (inductive load)
Number of Settings: 16 groups per day
Consumption Power: ≤2W
Battery: Ni-MH rechargeable battery (1.2V, 40mAh)
Time Error: ≤1s/day (25℃)
Dimensions: 98×55×40mm
Weight: 66g
Mounting: Wall/Rail

KG316T Series KG316T-Ⅱ (Single Output, Mini Size) image

Dimensions & Wiring Diagram


KG316T (Single Output, Upper Wire)

1 Single-phase power supply (there are two wiring methods)
1.1 Direct control method (as shown in Figure 1)
Applicable objects: Loads with single-phase power supply, and the power consumption does not exceed the rated capacity of the switch (resistive load 25A, inductive load 20A).
1.2 Single-phase expansion method (as shown in Figure 2)
Applicable objects: load with single-phase power supply, but the power consumption exceeds the rated capacity of the switch (resistive load 25A, inductive load 20A).
If this wiring method is adopted, the output terminal of the digital timer switch needs to be connected to a single phase AC contactor whose load capacity should larger than the power consumption of the load to expanse the switching capacity of the timer switch.

2 Three-phase power supply (requires an external three-phase AC contactor)
Applicable objects: Loads with three-phase power supply.
If the coil voltage of the three-phase AC contactor is AC220V/50Hz, the wiring method shown in Figure 3.
If the coil voltage of the three-phase AC contactor is AC380V/50Hz, the wiring method shown in Figure 4.

KG316T (single circuit, upper wiring) dimensions and wiring diagram

KG316T (single circuit, upper wiring) dimensions and wiring diagram

KG316T-D (Single Output, Down Wire)

There are two wiring methods for KG16T-D series, you can choose according to your needs.

KG316T-D (single circuit, down wiring) dimensions and wiring diagram

KG316T-D (single circuit, down wiring) dimensions and wiring diagram

KG316T-Ⅱ(Single Output, Mini Size)

There are two wiring methods for KG16T-Ⅱ series, you can choose according to your needs.

KG316T-Ⅱ (single circuit, mini size) dimensions and wiring diagram

KG316T-Ⅱ (single circuit, mini size) dimensions and wiring diagram

Instructions For Use (How to set)


Please make sure that you have understood the functions of all the buttons on the panel (button area), and perform the actual operation according to the instructions.

1 Description of buttons and indicators:

CLOCK (): Press to display your local time (it should be set by yourself: you can press and hold the "CLOCK" key to enter the "Time Adjustment Mode", and adjust the "WEEK", "HOUR", and "MINUTE" key to set the local time). PS: If no operation is performed within 30 seconds, the timer switch will automatically display the local time.
TIMER (): Press to enter the "Editing Mode", and then set the time to switch the load by adjusting the "WEEK", "HOUR", and "MINUTE" key.
WEEK (D+): Adjust week or day. There are various working modes, such as "Five-day Mode" (Monday to Friday), "Six-day Mode" (Monday to Saturday), "Weekend Mode" (Saturday, Sunday), "Daily Mode" (Monday to Sunday), and "Three-day Mode" (Mon-Wed-Fri; Tue-Thu-Sat; Mon-Tue-Wed; Thu-Fri-Sat).
HOUR (H+): Adjust hour.
MINUTE (M+): Adjust minute.
AUTO/MANU (MANUAL): Switch the three switching mode of "ON", "AUTO" and "OFF".
RESET/RECALL (Cancel/Restore, C/R): Press to cancel or restore the timing setting. PS: For products with button lock function, press the " RESET/RECALL " key four times to lock or unlock all buttons.
C: Long press the "C" key to clear all settings of the timer switch.
POWER LED: When the Power LED (red) is on, it means that the timer switch has been successfully connected to the power source.
WORK LED:  When the Power LED (red) and the Work LED (green) are on at the same time, it means that the load is powered on.

2 Operating instructions:

Step 1. Timing setting (on):

Press the " TIMER " button to enter the "Editing Mode". At this time, the "1ON" symbol will appear at the bottom left of the LCD screen (that is, the first time to turn on the load, as shown in Figure 9), and then press the "WEEK" to select Working Mode, and then press the "HOUR" and "MINUTE" keys to input the required switching on time.

Step 2. Timing setting (off):

Press the " TIMER " button again, the "1OFF" symbol will appear at the bottom left of the LCD screen (that is, the first time to turn off the load, as shown in Figure 10), and then press the "WEEK" to select Working Mode, and then press the "HOUR" and "MINUTE" keys to input the required switching off time. At this time, the first group of timing setting has been completed.

Step 3. Timing setting (number of groups):

After completing the first group of timing setting, press the "TIMER" button again, the LCD display will show the "2ON" symbol, and you can set the second set of time setting. According to actual needs, you can repeat steps 1 and 2 to set many groups (the maximum programmable group number depends on the product's built-in chip). If you want to exit the "Editing Mode", you can press the "CLOCK" key to exit it.

How to timing setting

Timing Setting1

Step 4. RESET/RECALL:

After setting a group of time, for example, turn on the load at 18:30 every day (Figure 11), and turn off the load at 23:20 every day (Figure 12). If you want to cancel this group, you can press the "RESET/RECALL" button to delete this group of time settings. At this time, the group of time will be reset to the initial state, that is, "--: --" (Figure 9 and Figure 10). Under certain conditions (without any key operation or switching to other interfaces within 20 seconds after cancel operation), just press the "RESET/RECALL" button again to restore this group of time settings.

Step 5. AUTO/MANU:

The timer switch has two switching modes: automatic and manual. In the automatic mode, the timer switch will be set according to the timing of steps 1 to 3, and the load will be automatically turned on or off at the corresponding time without human intervention. In manual mode, the load must be turned on or off by manual adjustment.
The specific operations are as follows:
1) If you need to turn on the load manually, you can click the "AUTO/MANU" button to switch the "▼" symbol on the display to the "ON" position (Figure 13). At this time, the load will always be in the on state and cannot be turned off automatically.
2) If you need to turn off the load manually, you can click the "AUTO/MANU" button to switch the "▼" symbol on the display to the "OFF" position (Figure 14). At this time, the load will always be in the off state and cannot be turned on automatically.
3) If you need to switch the load automatically, you can click the "AUTO/MANU" button to switch the "▼" symbol on the display to the "AUTO" position (Figure 15). At this time, the working state of the load will be switching automatically according to the timing setting, without being interfered by humans.

How to timing setting 2

Timing Setting2

Step 6. Lock and unlock:

For the timer switch with button lock (or keyboard lock), you can quick press the "RESET/RECALL" key four times to lock or unlock all the buttons.
-How to lock the buttons?
In the unlocked state, quick press the "RESET/RECALL" button four times or without any operation within 30 seconds to lock all the buttons (Figure 16). At this time, there will be a "∂" symbol in the bottom left, and you cannot make any settings for the timer switch.
-How to unlock buttons?
In the locked state, quick press the "RESET/RECALL" button four times to unlock all the buttons (Figure 17), and you can make settings at this time.

When you think there is a fault (FAQs)


Note: When the product fails, please disconnect the power first, and then check the equipment!
1 Check the week:
If the timer switch does not turn on or turn off the load at the set time, it may be that the "WEEK" is not adjusted correctly, please check or reset it according to the method introduced in "Timing Setting".
2 Check the time groups:
If the first point is confirmed to be correct, but the load still cannot be switched correctly on time, the reason will be that the extra time group has not been cancelled. Please refer to the method introduced in "Timing Setting" to delete it. PS: Only when the display shows "--: --", it means the time group is deleted successful; if it displays "00:00", it means 0 o'clock (24 o'clock), not the deleting success.
3 Check the switching mode:
If the above two points are confirmed to be correct, but the timer switch still does not work normally, it may be that the timer switch is working in "Manual Mode". You can first adjust the "AUTO/MANU" key to set the timer switch to the right working state of the load (ON or OFF), then switch to the "Automatic Mode".
4 Check the fuse:
If the above three points are correct and the timer switch still cannot work normally, please open the rear seat insurance cover (terminal cover) and check whether the fuse has been blown. If it is blown, please replace with a new 0.1A~0.3A fuse.
5 Check the power supply:
If the Work LED (or Output LED) is on when the timer switch is working, but the load cannot be switched normally, please check whether the voltage of the power supply is too low. If the timer switch is burned out, please check whether the power supply voltage exceeds the rated voltage of the product and whether the power cable is connected incorrectly.
6 Please replace the battery:
If the LCD screen does not display or the display is not clear, replace the battery with the same specification. (Only for timer switch with replaceable batteries)
7 Please contact us or local distributor:
If the fault cannot be eliminated by the above methods, please contact us or the distributor (dealer) in your local area.

Attentions


1 For those equipment (such as medical equipment and large equipment, etc.) that may cause life safety accidents or cause major harm to society due to the error of the timer switch, please do not choose this timer switch.
2 For those equipment (large heaters or cold storage, etc.) that may cause major property losses due to the error of the timer switch, ensure that there is sufficient design margin when using this timer switch, and take safeguard measures such as the double protection circuit.
3 Do not repair, disassemble or modify this timer switch by yourself. If you need to repair and check it, please be sure to entrust a dealership or other authorized unit.
4 Do not touch any terminal on the timer switch after it powered on.
5 This timer switch cannot work in humid, corrosive and high metal content gas environment. And do not let the timer switch come into contact with oil or water.